<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Heavy duty generator &#8211; Atwin Engineering &amp; Construction LTD</title>
	<atom:link href="https://atwinengineering.com/product-tag/heavy-duty-generator/feed/" rel="self" type="application/rss+xml" />
	<link>https://atwinengineering.com</link>
	<description>&#34;Smart Solutions for Water, Energy &#38; Beyond.&#34;</description>
	<lastBuildDate>Mon, 17 Feb 2025 11:34:38 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.3</generator>

<image>
	<url>https://atwinengineering.com/wp-content/uploads/2024/04/cropped-favicon-01-32x32.png</url>
	<title>Heavy duty generator &#8211; Atwin Engineering &amp; Construction LTD</title>
	<link>https://atwinengineering.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Perkins 13KVA Diesel Silent Generator Heavy Duty 3phase</title>
		<link>https://atwinengineering.com/product/perkins-13kva-diesel-silent-generator-heavy-duty-3phase/</link>
					<comments>https://atwinengineering.com/product/perkins-13kva-diesel-silent-generator-heavy-duty-3phase/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Sat, 06 Apr 2024 11:16:44 +0000</pubDate>
				<guid isPermaLink="false">https://atwinengineering.com/?post_type=product&#038;p=5712</guid>

					<description><![CDATA[Standard Equipment Print Engine Air Cleaner Lube oil drain valve Engine filled with lubrication oil High Coolant Temperature Shutdown &#160; &#160; Low Oil Pressure Shutdown Cooling Package mounted radiator Radiator]]></description>
										<content:encoded><![CDATA[<p>Standard Equipment</p>
<p>Print Engine</p>
<p>Air Cleaner</p>
<p>Lube oil drain valve</p>
<p>Engine filled with lubrication oil</p>
<p>High Coolant Temperature Shutdown</p>
<div aria-hidden="true">
<p>&nbsp;</p>
<div id="aswift_3_host"></div>
<p>&nbsp;</p>
</div>
<p>Low Oil Pressure Shutdown</p>
<p>Cooling</p>
<p>Package mounted radiator</p>
<p>Radiator &amp; Cooling Fan</p>
<p>Coolant Drain Valve</p>
<p>Fan, Fan drive and battery charging Alternator drive fully guarded to meet EC Machinery Directive</p>
<p>Cooling System filled with Coolant mix</p>
<p>Exhaust</p>
<p>Exhaust flange outlet</p>
<p>Exhaust stub pipe and gasket</p>
<div aria-hidden="true">
<p>&nbsp;</p>
<div id="aswift_4_host"></div>
<p>&nbsp;</p>
</div>
<p>Fuel</p>
<p>8 Hr Fuel Tank or Skidbase</p>
<p>Fuel Fittings for Local and Remote Feed</p>
<p>Alternator</p>
<p>FG Wilson Alternator</p>
<p>SHUNT Excitation</p>
<p>IP23 Protection</p>
<p>Control Panel</p>
<p>FG100</p>
<p>Mounting</p>
<p>Base, Formed Steel with Skid base or Single wall Fuel Tank</p>
<p>Certified Base Mounted Lifting Eyes, and Rear Drag Eyelets</p>
<p>Anti-vibration mounts</p>
<p>Battery Tray and Cables</p>
<p>Exhaust</p>
<div aria-hidden="true">
<p>&nbsp;</p>
<div id="aswift_6_host"></div>
<p>&nbsp;</p>
</div>
<p>Industrial, Residential, Critical Silencers</p>
<p>Alternator</p>
<p>Leroy Somer Alternator</p>
<p>Quadrature Droop Kit</p>
<p>Anti-Condensation Heater and Panel Circuitry</p>
<p>Control Panels</p>
<p>DSE4520</p>
<p>DSE7320</p>
<p>DSE7410</p>
<p>Deep Sea DSE7420</p>
<p>Starting/Charging</p>
<p>Lead Acid battery (Dry)</p>
<p>General</p>
<p>Upgrade to Standard Set for CE Certification</p>
<p>EEC Declaration of Conformity</p>
<p>Narrow, Wide or Skid Base</p>
<p>Sound attenuated, steel or galvanised enclosure</p>
<p>Dual wall fuel tanks</p>
<p>Enclosure</p>
<p>Compliance to European Community Directive 2000/14/EC</p>
<p>Super sound attenuation for residential areas</p>
<p>Totally enclosed exhaust silencing system</p>
<p>Robust and highly corrosion resistant construction</p>
]]></content:encoded>
					
					<wfw:commentRss>https://atwinengineering.com/product/perkins-13kva-diesel-silent-generator-heavy-duty-3phase/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Perkins 20KVA Diesel Silent Generator Heavy Duty 3phase</title>
		<link>https://atwinengineering.com/product/perkins-20kva-diesel-silent-generator-heavy-duty-3phase/</link>
					<comments>https://atwinengineering.com/product/perkins-20kva-diesel-silent-generator-heavy-duty-3phase/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Sat, 06 Apr 2024 11:12:38 +0000</pubDate>
				<guid isPermaLink="false">https://atwinengineering.com/?post_type=product&#038;p=5710</guid>

					<description><![CDATA[Generator Set Specifications Minimum Rating 20 kVA / 16 kW Maximum Rating 22 kVA / 17.6 kW Emissions/Fuel Strategy Fuel Optimised 50 Hz Prime 20 kVA / 16 kW 50]]></description>
										<content:encoded><![CDATA[<p>Generator Set Specifications</p>
<p>Minimum Rating 20 kVA / 16 kW</p>
<p>Maximum Rating 22 kVA / 17.6 kW</p>
<p>Emissions/Fuel Strategy Fuel Optimised</p>
<p>50 Hz Prime 20 kVA / 16 kW</p>
<p>50 Hz Standby 22 kVA / 17.6 kW</p>
<div aria-hidden="true">
<p>&nbsp;</p>
<div id="aswift_3_host"></div>
<p>&nbsp;</p>
</div>
<p>60 Hz Prime /</p>
<p>60 Hz Standby /</p>
<p>Frequency 50 Hz</p>
<p>Speed 1500 RPM</p>
<p>Voltage 220-415 Volts</p>
<p>50 Hz Prime Rating These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.</p>
<p>60 Hz Prime Rating These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3).</p>
<p>50 Hz Standby Rating Standard reference conditions 25C (77F) Air Inlet Temp, 100m (328 ft) A.S.L. 30% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2.</p>
<p>Engine Specifications</p>
<p>Engine Model Perkins 404A-22G1</p>
<div aria-hidden="true">
<p>&nbsp;</p>
<div id="aswift_4_host"></div>
<p>&nbsp;</p>
</div>
<p>Bore 84 mm (3.3 in)</p>
<p>Stroke 100 mm (3.9 in)</p>
<p>Governor Type Mechanical</p>
<p>Displacement 2.2l (135.2 cu. in)</p>
<p>Compression Ratio 23.3:1</p>
<p>Standard Equipment</p>
<p>print Print Engine</p>
<p>Air Cleaner</p>
<p>Lube oil drain valve</p>
<p>Engine filled with lubrication oil</p>
<p>High Coolant Temperature Shutdown</p>
<p>Low Oil Pressure Shutdown</p>
<p>Cooling</p>
<p>Package mounted radiator</p>
<p>Radiator &amp; Cooling Fan</p>
<div aria-hidden="true">
<p>&nbsp;</p>
<div id="aswift_6_host"></div>
<p>&nbsp;</p>
</div>
<p>Coolant Drain Valve</p>
<p>Fan, Fan drive and battery charging Alternator drive fully guarded to meet EC Machinery Directive</p>
<p>Cooling System filled with Coolant mix</p>
<p>Exhaust</p>
<p>Exhaust flange outlet</p>
<p>Exhaust stub pipe and gasket</p>
<p>Fuel</p>
<p>8 Hr Fuel Tank or Skidbase</p>
<p>Fuel Fittings for Local and Remote Feed</p>
<p>Alternator</p>
<p>FG Wilson Alternator</p>
<p>SHUNT Excitation</p>
<p>IP23 Protection</p>
<p>Control Panel</p>
<p>DSE4520</p>
<p>FG100</p>
<p>Mounting</p>
<p>Skid base, Formed Steel</p>
<p>Base, Formed Steel with Skid base or Single wall Fuel Tank</p>
<p>Certified Base Mounted Lifting Eyes, and Rear Drag Eyelets</p>
<p>Anti-vibration mounts</p>
<p>Battery Tray and Cables</p>
]]></content:encoded>
					